Electrical System
9.126
Model 6042 Legacy Origin 7/02
9.15.12 Transmission Temperature Switch
The transmission temperature switch (Fig. 9-120, 1) is
threaded into the transmission housing (2) and is
connected to the operators instrument cluster via the
engine wiring harness, bulkhead connector and cab
wiring harness.
Figure 9-120 Transmission High Temperature Switch
When the transmission fluid temperature rises above
250° F (121° C), the contacts close within the switch. The
operators instrument cluster indicator (Fig. 9-121, 1) illu-
minates.
Figure 9-121 Transmission Temperature Indicator
When the transmission temperature is below 250° F
(121° C), the contacts within the switch open and the op-
erators instrument cluster indicator turns off. (Refer to
Section 9.9.3, Transmission Temperature Warning Indi-
cator Troubleshooting.)
a. Transmission Temperature Switch Removal
1. Disconnect the negative () battery cable at the
negative battery terminal (Fig. 9-122, 1).
Figure 9-122 Battery Cable Connections
MA9010
1
2
0000 00
P
MA7580
1
MA8410
1